{"id":2739,"date":"2026-11-24T11:11:18","date_gmt":"2026-11-24T14:11:18","guid":{"rendered":"https:\/\/thermomac.com\/?p=2739"},"modified":"2026-11-24T11:11:20","modified_gmt":"2026-11-24T14:11:20","slug":"iiar-8-el-arte-de-apagar-un-sistema-sin-dejar-pasivos-escondidos","status":"publish","type":"post","link":"https:\/\/thermomac.com\/en\/iiar-8-el-arte-de-apagar-un-sistema-sin-dejar-pasivos-escondidos\/","title":{"rendered":"IIAR 8: the art of shutting down a system without leaving hidden liabilities"},"content":{"rendered":"<p class=\"wp-block-paragraph\"><strong>Refrigeration Insights series. Season 3: The IIAR standards, installment 9 of 10.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Refrigeration systems are always discussed in the future tense: the project, the expansion, the upgrade. The end is almost never discussed. But every ammonia system eventually reaches its final shutdown, and what is done that day determines whether the plant leaves behind a clean site or a liability hidden behind a closed valve.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For that day there is ANSI\/IIAR 8-2020, Decommissioning of Closed-Circuit Ammonia Refrigeration Systems.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What IIAR 8 is<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The standard sets out the minimum requirements for safe decommissioning: the criteria for removing the ammonia charge together with dismantling the system. It is intended for everyone involved in the process: owners, contractors, engineering firms and safety managers.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It applies to closed-circuit compression and absorption systems that use anhydrous ammonia or ammonia-water mixtures and are decommissioned after the standard is adopted. Packaged absorption systems with a charge below 10 kg (22 lb) are excluded, and there is an important distinction: a temporary shutdown is not decommissioning. Stopping a system for a while and dismantling it are different processes, with different requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The assumptions worth reading twice<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The foreword makes three starting assumptions explicit: that the system was designed for the service it performed, that the installed piping and electrical equipment are fully functional, and that there is adequate access to remove the charge safely.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Read the other way around, it is a warning: if your system reaches the end of its life with questionable piping, degraded electrical installations or blocked access, decommissioning does not start with the standard, it starts earlier, by restoring safe conditions so that it can be carried out. Systems abandoned without a plan are exactly the scenario the standard aims to prevent.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">It does not work alone<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Like the whole family, IIAR 8 relies on normative references: IIAR 1 for definitions and IIAR 6 for the inspection and maintenance status of the system being worked on. It makes sense: to safely empty and dismantle a system you need to know its real condition, and that condition is (or should be) in the ITM records.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The standard also warns that its minimum requirements may not be sufficient under other applicable regulations: environmental, waste and occupational safety. Decommissioning is a multidisciplinary project, and IIAR 8 is its technical backbone, not its only document.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why it matters in the region<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Across Latin America's industrial base, modern plants coexist with systems that have sat idle for decades \"just in case\", with ammonia charges no one has measured recently and responsible people who are no longer with the company. Each of those systems is a risk without an owner. IIAR 8 provides the framework to turn that limbo into a project with a beginning, an end and documentation.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Practical advice<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">If you have a system that has been out of operation for more than a year, ask yourself three questions: is it formally in temporary shutdown, or did nobody decide?, how much ammonia charge does it hold today?, who is the designated person in charge? If any answer is \"I don't know\", that system needs a decision: return to service under IIAR 9, or formal decommissioning under IIAR 8. The only thing that cannot be managed is limbo.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Next week we close the ammonia standards phase and open the door to the refrigerant that keeps growing: the IIAR CO2-2021 standard.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em>Source: ANSI\/IIAR 8-2020, Decommissioning of Closed-Circuit Ammonia Refrigeration Systems, International Institute of Ammonia Refrigeration. Thermomac is a corporate member of IIAR.<\/em><\/p>","protected":false},"excerpt":{"rendered":"<p>Serie Refrigeration Insights. Temporada 3: Las normas IIAR, entrega 9 de 10. De los sistemas de refrigeraci\u00f3n se habla siempre en tiempo futuro: el proyecto, la ampliaci\u00f3n, la mejora. Casi nunca se habla del final. Pero todo sistema de amon\u00edaco llega un d\u00eda a su \u00faltima parada, y lo que se haga ese d\u00eda define [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":2741,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"_joinchat":[],"footnotes":""},"categories":[16],"tags":[],"class_list":["post-2739","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-refrigeration-insights"],"_links":{"self":[{"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/posts\/2739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/comments?post=2739"}],"version-history":[{"count":1,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/posts\/2739\/revisions"}],"predecessor-version":[{"id":2740,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/posts\/2739\/revisions\/2740"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/media\/2741"}],"wp:attachment":[{"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/media?parent=2739"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/categories?post=2739"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/thermomac.com\/en\/wp-json\/wp\/v2\/tags?post=2739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}